Maikong High voltage therapy

Here’s a Quick Way high potential therapy japan


    

What is high potential therapy japan?

high-voltage electric field therapy unit that stimulates the entire body with a maximum voltage of 9000 V (peak value). The unit is used primarily to treat headache, muscle pain, insomnia, chronic constipation, and lumbago. Since a mattress electrode is used for the administraion of therapy, you can lie on a bed or sit in a chair and relax while receiving treatment. The output level, a timer, and whole-body/local treatment can be set using a simple, one-touch button. Three selectable output levels: 3000V, 6000V, and 9000V Three stimulation programs can be selected. The ooutput changes evey minute to prevent the body from accomodation to the stimulation, resulting in more effective treatment. The unit allows not only treatment of the entire body through the use of a mattress electrode, but also local treatment through the use of a point electrode. The treatment time can be selected from among 30 minutes, one hour, two hours, four hours, and eight hours.

How high potential therapy japan work?

EFT is a simple, non-invasive technique using static electricity which produces fast demonstrable clinical results. The theory is that when an electric filed with high voltage AC is applied on a human body, cells metabolism is stimulated by supplementing ions and the Acid-Base Balance of Electolyte in blood results adjusted.

The H+ flow of ions in the organism cars optimally be clirected.This is important because beside others, the co-ordinates of enzyme, the Ca++houselsold, tire proteins of transportation in the blood and the general acid-base-homeostasis depend on these flows of protons and ions.

Abnormal physiology is associated wills abnormal electrical activity.Correcting the abnormal electrical activity facilitates restoration of normal physiology.

Electric Field Therapy apparatus apply safe levels of high AC voltage potential to the body and create an electrical field around it.This electric field stimulates the sensory receptors in the skin, which in turn stimulates the hypothalamus and other areas of the brain, to promote homeostatic functions. Also, the electric field generates minute amounts of induced current, which permeates the body and stimulates the metabolism.

Why do we need or want to increase our Negative Potential or Negative Ions?
Negative Potential Energy increases the permeability of cell membranes and enhances the composition of ATP, which is responsible for transporting chemical energy within cells for metabolism.

  • Electric energy can help reactivate the cell membrane of more than 230 types of cells in our body.
  • Negative ion can help to adjust and recover weak body cell.

Why high potential therapy japan?

Even though recent reviews were unable to provide evidence of efficacy for several oral and topical complementary treatments for rheumatoid arthritis (RA), a group of researchers in Japan decided to clinically evaluate the effectiveness of static electric field therapy by high voltage alternating current (EF-HVAC) in the chronic inflammatory autoimmune disorder, given the method’s prevailing use in headache, shoulder stiffness, chronic constipation, and insomnia among patients who fail to respond to conventional therapies.

For their randomized, double-blind, sham-controlled study published in the July 2013 edition of the Journal of Clinical Biochemistry and Nutrition, Yuji Naito, MD, PhD, and colleagues from the Kyoto Prefectural University of Medicine treated 24 patients who fulfilled the American College of Rheumatology’s criteria for active RA diagnosis with either EF-HVAC therapy provided via medical equipment maker Cocoroca Corp.’s Legacis Plus System or sham therapy for 12 weeks, and then observed those patients for four weeks after treatment.

At baseline, four weeks, eight weeks, 12 weeks, and 16 weeks, the researchers calculated and compared the patients’ 28-joints disease activity scores based on C-reactive protein (DAS28-CRP), visual analogue scores (VAS) for pain, swollen joint scores, tender joint scores, modified health assessment questionnaire responses for arthritis functioning, as well as “changes in laboratory measures of biomarkers: erythrocyte sedimation rate (ESR), rheumatoid factor (RF), matrix metalloproteinase-3 (MMP-3), and CRP.”

How to operations the high potential therapy device?

Please operate in strict accordance with the following methods to ensure safe and

proper using the product

1. Emplace hosts. Flatly place the host on ventilation, dry easy-to-operation objects

(plastic or wooden tables and chairs). The host must maintain a distance of at least

20cm with the ground the wall. Host and energy pad must maintain a distance of at

least 1 m with computers and other appliances. It should be placed a insulated pad

on the ground for foot placing. See diagram

2. Connect energy pad and power source. Making energy sitting pad (mattress) set

smoothly on the plastic or the dry lignin chair (bed). The energy pad and wire cannot

touch with the ground, the spacing maintain above 20cm. Insert the plug into

220V/50Hz socket.

3. Turn on the host power source, Chinese character lightens the demonstration

completely, the host enters the readiness for action, the timer demonstration is

30:00 minute.
4. Function choice:

A
Before choosing high potential function, inserting the energy pad and effect pad input plug

into host’s high potential output hole, pressing the high potential key 7, the high potential output

may choose the 5000V,7000V,9000V of three kinds of intensities.

B
Before choosing negative potential function, inserting the energy pad and effect pad input plug

into host’s negative potential output hole, presses the negative potential key 8, the negative

potential output may Choose-5000V,-6000V,-7000V of three kinds of intensities.

C
Before choosing intermediate potential function, inserting the energy pad and effect pad input

plug into host’s intermediate potential output hole, presses the intermediate potential key 9,

intermediate potential output specification are 2800Vp-p,80KHz.

D
When using the intelligent treatment, making the energy pad high pressure input

line’s plug inserts into the host’s high potential output hole/negative potential output

hole, pressing the intelligent key 11, electric potential output intensity is made by

5 minutes gap intelligence circulation of output high potential/negative potential.

5. Adjusting time. Presses the time key to set the time, presses to hand over by

10 minutes/grade for each time, from default 30:00, to 40:00, 50:00 ……

Until 90:00 increasing. The most greatly fixed time for the countdown time is

90 minutes. When countdown, the time demonstrates for the first two digital

presentations are minutes, the latter two digital presentations are seconds.

After arriving at 90:00, presses one time to return to 0:00 again. 0:00 indicated

enters the sleep function of time reference point. The sleep function is started by

0 hours 00 minutes. When sleep function, the first two digital presentation are hours,

the latter two digital presentation is minutes, the max time work is up to 12 hours,

it will close the sleep function after 12:00.

6.
A
After setting treatment function and treatment time, after pressing start/stop

key, the machine starts to work, the timer countdown, after the period of using

arrives, the buzzer sounds 10 times to remind the treatment has completed and

withdraw from this treatment function.

B
From step 4 to operate if the user would like to operate continuously.

C
After setting treatment function and treatment time, if the user do not press

start/stop key after 20 seconds, the machine would withdraw selected treatment

function and treatment time

7. The anoin treatment function may use with the above function, also may use

separately.

8. After using, please switch off the host power, separate the power point; make

the host at the power-off condition.

Here’s a Quick Way high potential therapy japan

high potential therapy japan

high potential therapy japan pdf

 

 benefits of high potential therapy electrostatic

high potential therapy 

high electric potential therapy 

high potential electrostatic field therapy 

high potential negative ion therapy 

high potential therapy

 

 



We are high voltage therapy machine,high voltage therapy physiotherapy,high voltage physical therapy,high voltage current therapy,high voltage shock therapy,high voltage electric field therapy,high voltage stimulation physical therapy,high voltage electric potential therapy,high-voltage static current therapy,what is high voltage therapy manufacturer,high voltage therapy machine wholesale, Offer different model of high voltage therapy machine,Offer factory Wholesale price.Welcome to inquiry and OEM,if you need the high voltage therapy machine price and Here’s a Quick Way high potential therapy japan price list,please cotnact us.


Production, sale, offer OEM & ODM .


Our advantage(Why choose us?):

1.Original high voltage therapy machine.

2.OEM high voltage therapy machine Accepted.

3.In stock high voltage therapy machine best price.

4.Professional after sales service.

5.Different language version.

6.Free upgrade forever.

7.Wholesale price.

8.CE Cetificate.




    

Contact US Onlone By WhatsAPP:

Have any question, Please enter the form below and click the submit button.


*
*
*
* + * = ?
Please enter the answer to the sum & Click Submit to verify your registration.

If the submission is unsuccessful, please refresh your browser page and resubmit.


CATEGORY AND TAGS:

high electric potential, High Potential Therapy Device, high voltage electric field therapy, High voltage electrostatic therapy equipment

, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Related Items